Cut to length line supplier factory from China
Electrical equipment manufacturer factory with Canwin: Heating of Cables, Motors, and Transformers: Poor power quality can lead to excessive heating in cables, motors, and transformer core cutting machine. This can accelerate the ageing of these components, shorten their lifespan, and potentially lead to catastrophic failures. Maintaining high power quality, including minimizing voltage unbalances, is critical for ensuring the efficient operation of electrical equipment and avoiding the potential negative consequences associated with poor power quality. In conclusion, maintaining high power quality is of paramount importance for the optimal performance and longevity of transformer equipment. High-quality power ensures efficient energy consumption, reduces operational costs, and extends the lifespan of the equipment. It also minimizes the risk of malfunctions, data corruption, and excessive heating of cables, motors, and transformers – issues often associated with poor power quality. Read extra information on cut to length line manufacturers.
Why should the iron core of the transformer be grounded? Transformer core grounding is for safety and electromagnetic compatibility considerations. On the one hand, grounding the transformer core prevents contact voltages caused by ground faults, which can pose a shock hazard to humans. Because when a ground fault occurs on one side of the transformer, the iron core on the other side may have a voltage in contact with the earth. If it is not grounded, this voltage cannot be released. On the other hand, grounding the transformer core can also reduce electromagnetic radiation interference, especially for radio equipment and communication systems. This is because the current will generate a magnetic field in the iron core. If the iron core is not grounded, this magnetic field may leak into the surrounding environment and interfere with the normal operation of other equipment. In conclusion, grounding the transformer core is a protective measure against shock hazards and electromagnetic interference.
Why does the current source inverter need a larger transformer capacity? Current source inverter is a common type of inverter. Its control method adopts current loop control, which has the advantages of high precision and strong adaptability, and is widely used in industrial production. Due to the working characteristics of the current source inverter, a large transformer capacity is required for the following reasons: The current source inverter adopts the intermediate inductance: the current source inverter adopts the intermediate inductor, which can realize the phase difference between the output voltage and the current, so as to realize the frequency conversion control. However, since the intermediate inductor needs to withstand large current and voltage, it is necessary to select a transformer with a larger capacity to ensure the normal operation of the inductor.
As a professional electrical equipment manufacturer in China, Canwin specialized in dry type transformers, electrical equipment for over 20 years. Canwin electrical products manufacturer adopts large-scale, intelligent electrical machinery equipment manufacturing mode, and strive to achieve high quality, high efficiency, low cost operation.Our electrical machinery products including cut to length lines, china slitting lines and foil winding machines.
CANWIN AUTOMATICEQUIPMENT CO.,LTD is a global leading foil winding machine supplier & manufacturer with over 20 years of experiences.Ribbon foil winding machine has unique appearance, convenient operation, intuitive data display, high degree of automation, and is well received by users. This foil winding machine is widely used in oil-immersed transformer, dry transformer, special transformer and reactor production required. Foil coils are of different thicknesses copper or aluminum foil as a conductor, with wide ribbon insulation material as the insulation between layers, with narrow ribbon insulation material as the end insulation, completed winding one time, forming a coil. The inner and outer leads of the coil are welded and wrapped up at the same time.
Three-dimensional wound core transformer breaks through the traditional triangle plane structure, adopts three-phase symmetric vertical structure, magnetic circuit completely symmetrical three-phase core products, magnetic resistance is greatly reduced, excitation current, no-load loss, is a kind of using traditional materials, but lower operating noise, structure is more compact and efficient energy-saving oil type transformer. Its excellent performance in energy saving and energy saving and environmental protection is in line with China’s energy conservation policy.
The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.
The loss in magnetic flux in the transformer must therefore be minimized by providing a suitable mean between the primary and secondary windings. For this purpose, silicon steel magnetic cores are usually used. By using a core type transformer, magnetic losses are reduced and a greater amount of magnetic flux is conveyed between the primary and secondary coils, thereby increasing the transformer’s overall efficiency. Electrical materials play an important role in the field of engineering technology. Various technologies should be realized through certain equipment, and the equipment needs to be made of specific materials. Without corresponding materials, even technologies and products that are feasible in principle cannot be realized. The emergence of new materials can often bring significant technological progress. Read more information at https://www.canwindg.com/
Laser welding machine is an efficient and precise welding method using high energy density laser beam as a heat source. Laser welding is one of the important applications of laser material processing technology. It mainly used for welding thin wall material and low speed in the 1970 s. The welding process is thermal conduction, i.e. the laser radiation heating surface, the surface heat to the internal diffusion through heat conduction, by controlling the width of laser pulse, energy, peak power and repeating frequency, parameters such as melting of components, to form specific molten pool. Because of its unique advantages, it has been successfully used in precision welding of micro and small parts.As one of the best laser welding machine manufacturers in China, Canwin specialized in handheld laser welding machine and wholesale fiber laser welding machine making for over 20 years.
Digital measurement – Digital measurement of transformers or other components can be conducted, and the measurement results can be called and collected from the process layer and station control layer through digital networks, thus monitoring transformers and other equipment.Status visualization – The operation status of transformers can be visualized and observed in the power grid.Smart grid or other related systems can express the status information of transformer self-detection or information interaction.
Insulation level: There are standards for insulation levels. The insulation level of a transformer with a rated high voltage of 35 kV and a rated low voltage of 10 kV is represented as LI200AC85/LI75AC35, where LI200 indicates that the transformer has a high-voltage lightning impulse withstand voltage of 200 kV, a power frequency withstand voltage of 85 kV, and a low-voltage lightning impulse withstand voltage of 75 kV, and a power frequency withstand voltage of 35 kV. The current insulation level of Aux High-Tech Co., Ltd.’s oil-immersed transformer products is LI75AC35, indicating that the transformer has a high-voltage lightning impulse withstand voltage of 75 kV and a power frequency withstand voltage of 35 kV. Because the low voltage is 400 V, it can be ignored.